Synchronization

On the Synchronization tab, you can configure different synchronization options for the device.

Audio - Synchronization tab

System Sample Rate

You can adjust the sample rate of a device to 48 kHz or 44.1 kHz.

warning

Even if the device works with external synchronization, you have to set the correct sample frequency here, because the internal Quartz PLL can not adjust correctly to the external clock otherwise.

Synchronization Sources

You can define two synchronization sources on 52/XD3 and 52/XC3 - Sync Source and Sync Source 2.

The source configured at Sync Source is the primary synchronization source. If this sync source fails, the system automatically changes to the source configured in the Sync Source 2 list. If the second sync source fails too, the system switches to the internal clock of 48 kHz or 44.1 kHz, depending on the selection above.

Sync sources can only be signals that are connected directly to the core. Cores with integrated MADI interface (52-7321, 52-7325, 52-1821 or 52-1825) can sync to that source. Otherwise an external BNC sync needs to be connected. The type of BNC source signal has to be selected on selecting source.

Also direct APC links or Gigabit Audio (GA) links between DSP Cores can be used as a sync source.

Selection of synchronization sources

Available sync signal options

Sync Signal Type52/XD3 cores52XC3 cores
Internal clockYesYes
BNC: WordclockYesYes
BNC: AES11YesYes
BNC: PAL/NTSCYesYes
BNC: HD Tri-LevelYesYes
MADI 1YesYes
GA 2YesYes
APC 3YesYes
AES67/Dante Core Extension Slot4YesYes

1 optional MADI module (52-7593, 52-7594, 52-7521 or 52-7325) required

2 optional XC Gigabit Audio port (52-7591, 52-7592, 52-7391 or 52-7395) required

3 additional license required: 52-8582 - XC/XS Core Audio Network

4 integrated AES67 RAVENNA interface 52-7567, 50-7067, Dante module 52-7080, 52-7580, 52-7585 or 4ch/4ch interface required